Hub · Energie & Technik
Solarwerk
11 veröffentlichte Endpunkt-URLs. Methoden, Preise, Eingaben und Originaldokumentation auf jeder Detailseite.
solar.halowerk.com · Katalogstand 2026-11-01, 15:19 UTC
Endpunkte
1–11 von 11- Solarwerk0,003 USDC
autonomy forecast
POSThttps://solar.halowerk.com/autonomy-forecastDaily energy balance and straight run-down from the figures supplied. Solar input is caller data in watt-hours per day; nothing is fetched and no weather is assumed. Time to empty means time to the reserve floor, not to zero. Idle draw and
- Solarwerk0,004 USDC
battery cycle
POSThttps://solar.halowerk.com/battery-cycleIntegrates the supplied current over time by the trapezoidal rule, so the result is only as good as the sampling interval; gaps longer than the stated max_gap_seconds are excluded and reported. Sign convention: positive current is charging,
- Solarwerk0,004 USDC
building heat demand
POSThttps://solar.halowerk.com/building-heat-demandComputes a transparent planning estimate for space-heating demand. The method is not DIN, VDI, GEG or PHPP and must not be used as regulatory proof. It combines transmission heat loss from each envelope component, ventilation heat loss from
- Solarwerk0,003 USDC
clear sky yield
POSThttps://solar.halowerk.com/clear-sky-yieldThis is an astronomical and geometric calculation, not a forecast. It assumes a cloudless sky and states the models used; real yield is lower whenever there is cloud, haze, snow, soiling or high cell temperature. The system_derate factor co
- Solarwerk0,002 USDC
inverter load check
POSThttps://solar.halowerk.com/inverter-load-checkContinuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of
- Solarwerk0,002 USDC
inverter losses
POSThttps://solar.halowerk.com/inverter-lossesCable loss uses the DC resistance of the two-way run at twenty degrees Celsius; warm cable in a hot compartment carries roughly four percent more resistance per ten kelvin, which is not applied. Inverter loss follows a three-part model of i
- Solarwerk0,003 USDC
low wattage cooking
POSThttps://solar.halowerk.com/low-wattage-cookingUses rated electrical power, food mass, start and target temperature, specific heat and an explicit efficiency range supplied by the caller. Optional vessel heat, evaporation and a caller-defined hold phase can be included. It contains no r
- Solarwerk0,005 USDC
off grid weather alarm
POSThttps://solar.halowerk.com/off-grid-weather-alarmUses the nearest current DWD MOSMIX_L station forecast, or a station explicitly supplied by the caller. Global irradiance drives a transparent PV estimate and forecast wind speed drives a stated generic turbine curve; neither replaces a sit
- Solarwerk0,002 USDC
shadow simulator
POSThttps://solar.halowerk.com/shadow-simulatorPure astronomy and geometry on level ground: sun position by the NOAA method, shadow length as object height divided by the tangent of the sun elevation. Refraction is only applied to sunrise and sunset. Terrain slope, surrounding buildings
- Solarwerk0,003 USDC
tilt optimiser
POSThttps://solar.halowerk.com/tilt-optimiserEvaluates clear-sky irradiance in the module plane for tilt angles from zero to ninety degrees on the fifteenth of each month and sums the days. Because it assumes a cloudless sky, the optimum leans slightly steeper than a real-weather opti
- Solarwerk0,003 USDC
victron log parse
POSThttps://solar.halowerk.com/victron-log-parseReads the key-tab-value lines of the VE.Direct text protocol, applies the unit scaling that belongs to each key, and decodes the charger state, tracker state and error number into plain text. Multiple blocks in one dump are returned as sepa