inverter load check

Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the response, they are not device data.

POST https://solar.halowerk.com/inverter-load-check

Eingaben

Felder des veröffentlichten Eingabeschemas
FeldTypPflichtBeschreibung
inverterobjectJa
loadsarrayJa
battery_voltage_vnumberNeinFor the DC current figure. Without it that field stays null.
Vollständiges Eingabeschema anzeigen
{
  "type": "object",
  "required": [
    "inverter",
    "loads"
  ],
  "additionalProperties": false,
  "properties": {
    "inverter": {
      "type": "object",
      "required": [
        "continuous_w"
      ],
      "additionalProperties": false,
      "properties": {
        "continuous_w": {
          "type": "number",
          "minimum": 50,
          "maximum": 100000
        },
        "surge_w": {
          "type": "number",
          "minimum": 50,
          "maximum": 400000,
          "description": "Peak rating. Defaults to twice the continuous rating."
        },
        "efficiency": {
          "type": "number",
          "minimum": 0.5,
          "maximum": 1,
          "default": 0.9
        },
        "idle_w": {
          "type": "number",
          "minimum": 0,
          "maximum": 500,
          "default": 15
        }
      }
    },
    "loads": {
      "type": "array",
      "minItems": 1,
      "maxItems": 60,
      "items": {
        "type": "object",
        "required": [
          "name",
          "watts"
        ],
        "additionalProperties": false,
        "properties": {
          "name": {
            "type": "string"
          },
          "watts": {
            "type": "number",
            "minimum": 0.1,
            "maximum": 50000
          },
          "quantity": {
            "type": "integer",
            "minimum": 1,
            "maximum": 200,
            "default": 1
          },
          "type": {
            "type": "string",
            "description": "Appliance class: resistive, electronics, led, motor, pump, compressor, induction."
          },
          "simultaneous": {
            "type": "boolean",
            "default": true,
            "description": "False if the appliance never runs together with the others."
          },
          "surge_factor": {
            "type": "number",
            "minimum": 1,
            "maximum": 12
          },
          "power_factor": {
            "type": "number",
            "minimum": 0.3,
            "maximum": 1
          }
        }
      }
    },
    "battery_voltage_v": {
      "type": "number",
      "minimum": 6,
      "maximum": 1000,
      "description": "For the DC current figure. Without it that field stays null."
    }
  }
}

Originalschema öffnen

Veröffentlichtes Eingabebeispiel

{
  "inverter": {
    "continuous_w": 50,
    "efficiency": 0.9,
    "idle_w": 15
  },
  "loads": [
    {
      "name": "beispiel",
      "watts": 0.1,
      "quantity": 1,
      "simultaneous": true
    }
  ]
}

Ergebnis & Dokumentation

Veröffentlichtes Ergebnisschema anzeigen
{
  "$ref": "https://solar.halowerk.com/inverter-load-check/schema#/outputSchema"
}