Solarwerk
off grid weather alarm
Uses the nearest current DWD MOSMIX_L station forecast, or a station explicitly supplied by the caller. Global irradiance drives a transparent PV estimate and forecast wind speed drives a stated generic turbine curve; neither replaces a site-specific yield model. A constant hourly load and optional battery are simulated over 12 to 120 hours. The result is an installation-risk signal, not an official weather warning, emergency alert or guarantee of supply.
POST https://solar.halowerk.com/off-grid-weather-alarmEingaben
| Feld | Typ | Pflicht | Beschreibung |
|---|---|---|---|
| station_id | string | Nein | Optional DWD MOSMIX station id. Use this or coordinates. |
| lat | number | Nein | |
| lon | number | Nein | |
| max_station_distance_km | number | Nein | |
| forecast_hours | integer | Nein | |
| load_wh_per_day | number | Ja | |
| solar | object | Nein | |
| wind | object | Nein | |
| battery | object | Nein | |
| alert | object | Nein | |
| include_series | boolean | Nein |
Vollständiges Eingabeschema anzeigen
{
"type": "object",
"required": [
"load_wh_per_day"
],
"additionalProperties": false,
"properties": {
"station_id": {
"type": "string",
"pattern": "^[A-Za-z0-9]{4,5}$",
"description": "Optional DWD MOSMIX station id. Use this or coordinates."
},
"lat": {
"type": "number",
"minimum": -90,
"maximum": 90
},
"lon": {
"type": "number",
"minimum": -180,
"maximum": 180
},
"max_station_distance_km": {
"type": "number",
"minimum": 1,
"maximum": 300,
"default": 80
},
"forecast_hours": {
"type": "integer",
"minimum": 12,
"maximum": 120,
"default": 72
},
"load_wh_per_day": {
"type": "number",
"minimum": 1,
"maximum": 10000000
},
"solar": {
"type": "object",
"additionalProperties": false,
"properties": {
"capacity_wp": {
"type": "number",
"minimum": 0,
"maximum": 10000000
},
"performance_ratio": {
"type": "number",
"minimum": 0.1,
"maximum": 1,
"default": 0.78
}
}
},
"wind": {
"type": "object",
"additionalProperties": false,
"properties": {
"capacity_w": {
"type": "number",
"minimum": 0,
"maximum": 10000000
},
"cut_in_m_s": {
"type": "number",
"minimum": 0.5,
"maximum": 10,
"default": 3
},
"rated_m_s": {
"type": "number",
"minimum": 2,
"maximum": 30,
"default": 12
},
"cut_out_m_s": {
"type": "number",
"minimum": 5,
"maximum": 60,
"default": 25
}
}
},
"battery": {
"type": "object",
"required": [
"capacity_wh",
"soc_percent"
],
"additionalProperties": false,
"properties": {
"capacity_wh": {
"type": "number",
"minimum": 10,
"maximum": 100000000
},
"soc_percent": {
"type": "number",
"minimum": 0,
"maximum": 100
},
"reserve_soc_percent": {
"type": "number",
"minimum": 0,
"maximum": 90,
"default": 20
},
"charge_efficiency": {
"type": "number",
"minimum": 0.5,
"maximum": 1,
"default": 0.95
},
"discharge_efficiency": {
"type": "number",
"minimum": 0.5,
"maximum": 1,
"default": 0.95
}
}
},
"alert": {
"type": "object",
"additionalProperties": false,
"properties": {
"renewable_coverage_percent": {
"type": "number",
"minimum": 0,
"maximum": 100,
"default": 50
},
"minimum_duration_hours": {
"type": "integer",
"minimum": 3,
"maximum": 48,
"default": 6
}
}
},
"include_series": {
"type": "boolean",
"default": true
}
}
}Veröffentlichtes Eingabebeispiel
{
"lat": 52.52,
"lon": 13.405,
"forecast_hours": 72,
"load_wh_per_day": 4200,
"solar": {
"capacity_wp": 2400,
"performance_ratio": 0.78
},
"wind": {
"capacity_w": 800,
"cut_in_m_s": 3,
"rated_m_s": 12,
"cut_out_m_s": 25
},
"battery": {
"capacity_wh": 9600,
"soc_percent": 72,
"reserve_soc_percent": 20
},
"alert": {
"renewable_coverage_percent": 50,
"minimum_duration_hours": 6
}
}Ergebnis & Dokumentation
Maschinenlesbare Dokumentation dieses Hubs
Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.
Weitere Endpunkte dieses Hubs
- Solarwerk0,003 USDC
autonomy forecast
POSThttps://solar.halowerk.com/autonomy-forecastDaily energy balance and straight run-down from the figures supplied. Solar input is caller data in watt-hours per day; nothing is fetched and no weather is assumed. Time to empty means time to the reserve floor, not to zero. Idle draw and
- Solarwerk0,004 USDC
battery cycle
POSThttps://solar.halowerk.com/battery-cycleIntegrates the supplied current over time by the trapezoidal rule, so the result is only as good as the sampling interval; gaps longer than the stated max_gap_seconds are excluded and reported. Sign convention: positive current is charging,
- Solarwerk0,004 USDC
building heat demand
POSThttps://solar.halowerk.com/building-heat-demandComputes a transparent planning estimate for space-heating demand. The method is not DIN, VDI, GEG or PHPP and must not be used as regulatory proof. It combines transmission heat loss from each envelope component, ventilation heat loss from