Solarwerk
inverter losses
Cable loss uses the DC resistance of the two-way run at twenty degrees Celsius; warm cable in a hot compartment carries roughly four percent more resistance per ten kelvin, which is not applied. Inverter loss follows a three-part model of idle draw, a proportional share and a quadratic share, fitted so that the stated peak efficiency is met near half of the rated power.
POST https://solar.halowerk.com/inverter-lossesEingaben
| Feld | Typ | Pflicht | Beschreibung |
|---|---|---|---|
| load_w | number | Ja | AC power drawn at the output. |
| battery_voltage_v | number | Ja | |
| inverter | object | Nein | |
| cable | object | Nein | |
| max_voltage_drop_percent | number | Nein |
Vollständiges Eingabeschema anzeigen
{
"type": "object",
"required": [
"load_w",
"battery_voltage_v"
],
"additionalProperties": false,
"properties": {
"load_w": {
"type": "number",
"minimum": 1,
"maximum": 100000,
"description": "AC power drawn at the output."
},
"battery_voltage_v": {
"type": "number",
"minimum": 6,
"maximum": 1000
},
"inverter": {
"type": "object",
"additionalProperties": false,
"properties": {
"rated_w": {
"type": "number",
"minimum": 50,
"maximum": 100000,
"default": 1200
},
"peak_efficiency": {
"type": "number",
"minimum": 0.5,
"maximum": 0.99,
"default": 0.93
},
"idle_w": {
"type": "number",
"minimum": 0,
"maximum": 500,
"default": 15
},
"efficiency_at_load": {
"type": "number",
"minimum": 0.3,
"maximum": 0.99,
"description": "Measured efficiency at this exact load, overrides the model."
}
}
},
"cable": {
"type": "object",
"required": [
"length_m",
"cross_section_mm2"
],
"additionalProperties": false,
"properties": {
"length_m": {
"type": "number",
"minimum": 0.1,
"maximum": 200,
"description": "One-way run; the calculation doubles it."
},
"cross_section_mm2": {
"type": "number",
"minimum": 0.5,
"maximum": 500
},
"material": {
"type": "string",
"enum": [
"copper",
"aluminium"
],
"default": "copper"
}
}
},
"max_voltage_drop_percent": {
"type": "number",
"minimum": 0.5,
"maximum": 10,
"default": 3
}
}
}Veröffentlichtes Eingabebeispiel
{
"load_w": 1,
"battery_voltage_v": 6,
"max_voltage_drop_percent": 3
}Ergebnis & Dokumentation
Veröffentlichtes Ergebnisschema anzeigen
{
"$ref": "https://solar.halowerk.com/inverter-losses/schema#/outputSchema"
}Veröffentlichtes Ergebnisbeispiel öffnen
Maschinenlesbare Dokumentation dieses Hubs
Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.
Weitere Endpunkte dieses Hubs
- Solarwerk0,003 USDC
autonomy forecast
POSThttps://solar.halowerk.com/autonomy-forecastDaily energy balance and straight run-down from the figures supplied. Solar input is caller data in watt-hours per day; nothing is fetched and no weather is assumed. Time to empty means time to the reserve floor, not to zero. Idle draw and
- Solarwerk0,004 USDC
battery cycle
POSThttps://solar.halowerk.com/battery-cycleIntegrates the supplied current over time by the trapezoidal rule, so the result is only as good as the sampling interval; gaps longer than the stated max_gap_seconds are excluded and reported. Sign convention: positive current is charging,
- Solarwerk0,004 USDC
building heat demand
POSThttps://solar.halowerk.com/building-heat-demandComputes a transparent planning estimate for space-heating demand. The method is not DIN, VDI, GEG or PHPP and must not be used as regulatory proof. It combines transmission heat loss from each envelope component, ventilation heat loss from