inverter losses

Cable loss uses the DC resistance of the two-way run at twenty degrees Celsius; warm cable in a hot compartment carries roughly four percent more resistance per ten kelvin, which is not applied. Inverter loss follows a three-part model of idle draw, a proportional share and a quadratic share, fitted so that the stated peak efficiency is met near half of the rated power.

POST https://solar.halowerk.com/inverter-losses

Eingaben

Felder des veröffentlichten Eingabeschemas
FeldTypPflichtBeschreibung
load_wnumberJaAC power drawn at the output.
battery_voltage_vnumberJa
inverterobjectNein
cableobjectNein
max_voltage_drop_percentnumberNein
Vollständiges Eingabeschema anzeigen
{
  "type": "object",
  "required": [
    "load_w",
    "battery_voltage_v"
  ],
  "additionalProperties": false,
  "properties": {
    "load_w": {
      "type": "number",
      "minimum": 1,
      "maximum": 100000,
      "description": "AC power drawn at the output."
    },
    "battery_voltage_v": {
      "type": "number",
      "minimum": 6,
      "maximum": 1000
    },
    "inverter": {
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "rated_w": {
          "type": "number",
          "minimum": 50,
          "maximum": 100000,
          "default": 1200
        },
        "peak_efficiency": {
          "type": "number",
          "minimum": 0.5,
          "maximum": 0.99,
          "default": 0.93
        },
        "idle_w": {
          "type": "number",
          "minimum": 0,
          "maximum": 500,
          "default": 15
        },
        "efficiency_at_load": {
          "type": "number",
          "minimum": 0.3,
          "maximum": 0.99,
          "description": "Measured efficiency at this exact load, overrides the model."
        }
      }
    },
    "cable": {
      "type": "object",
      "required": [
        "length_m",
        "cross_section_mm2"
      ],
      "additionalProperties": false,
      "properties": {
        "length_m": {
          "type": "number",
          "minimum": 0.1,
          "maximum": 200,
          "description": "One-way run; the calculation doubles it."
        },
        "cross_section_mm2": {
          "type": "number",
          "minimum": 0.5,
          "maximum": 500
        },
        "material": {
          "type": "string",
          "enum": [
            "copper",
            "aluminium"
          ],
          "default": "copper"
        }
      }
    },
    "max_voltage_drop_percent": {
      "type": "number",
      "minimum": 0.5,
      "maximum": 10,
      "default": 3
    }
  }
}

Originalschema öffnen

Veröffentlichtes Eingabebeispiel

{
  "load_w": 1,
  "battery_voltage_v": 6,
  "max_voltage_drop_percent": 3
}

Ergebnis & Dokumentation

Veröffentlichtes Ergebnisschema anzeigen
{
  "$ref": "https://solar.halowerk.com/inverter-losses/schema#/outputSchema"
}

Veröffentlichtes Ergebnisbeispiel öffnen

Maschinenlesbare Dokumentation dieses Hubs

Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.

Weitere Endpunkte dieses Hubs

Alle Endpunkte dieses Hubs →