Zum Inhalt
HALOWERK

Iotwerk

sensor calibration

Fits reference = slope × observed + offset with ordinary least squares over paired caller-supplied readings. It reports residual diagnostics and does not claim traceability, uncertainty accreditation or suitability beyond the supplied calibration range.

POST https://iot.halowerk.com/v1/sensor-calibration

Eingaben

Felder des veröffentlichten Eingabeschemas
FeldTypPflichtBeschreibung
observedarrayJa
referencearrayJa
Vollständiges Eingabeschema anzeigen
{
  "type": "object",
  "required": [
    "observed",
    "reference"
  ],
  "additionalProperties": false,
  "properties": {
    "observed": {
      "type": "array",
      "minItems": 2,
      "maxItems": 10000,
      "items": {
        "type": "number",
        "minimum": -1000000000000,
        "maximum": 1000000000000
      }
    },
    "reference": {
      "type": "array",
      "minItems": 2,
      "maxItems": 10000,
      "items": {
        "type": "number",
        "minimum": -1000000000000,
        "maximum": 1000000000000
      }
    }
  }
}

Originalschema öffnen

Veröffentlichtes Eingabebeispiel

{
  "observed": [
    0.1,
    10.2,
    20.3,
    30.1
  ],
  "reference": [
    0,
    10,
    20,
    30
  ]
}

Ergebnis & Dokumentation

Veröffentlichtes Ergebnisschema anzeigen
{
  "$ref": "https://iot.halowerk.com/v1/sensor-calibration/schema#/outputSchema"
}

Veröffentlichtes Ergebnisbeispiel öffnen

Maschinenlesbare Dokumentation dieses Hubs

Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.