Zum Inhalt
HALOWERK

Iotwerk

battery degradation

Applies a transparent heuristic: cycle fade scales with equivalent full cycles and depth-of-discharge exponent; calendar fade scales with square-root time and a temperature factor. Coefficients are caller supplied or declared defaults. This is not cell-chemistry validation, warranty advice or a safety prognosis.

POST https://iot.halowerk.com/v1/battery-degradation

Eingaben

Felder des veröffentlichten Eingabeschemas
FeldTypPflichtBeschreibung
initial_capacity_ahnumberJa
equivalent_full_cyclesnumberJa
average_depth_of_discharge_percentnumberJa
average_temperature_cnumberJa
calendar_daysnumberJa
cycle_fade_per_full_cycle_percentnumberNein
calendar_fade_per_sqrt_year_percentnumberNein
Vollständiges Eingabeschema anzeigen
{
  "type": "object",
  "required": [
    "initial_capacity_ah",
    "equivalent_full_cycles",
    "average_depth_of_discharge_percent",
    "average_temperature_c",
    "calendar_days"
  ],
  "additionalProperties": false,
  "properties": {
    "initial_capacity_ah": {
      "type": "number",
      "minimum": 0.001,
      "maximum": 1000000000
    },
    "equivalent_full_cycles": {
      "type": "number",
      "minimum": 0,
      "maximum": 1000000000
    },
    "average_depth_of_discharge_percent": {
      "type": "number",
      "minimum": 0,
      "maximum": 100
    },
    "average_temperature_c": {
      "type": "number",
      "minimum": -50,
      "maximum": 150
    },
    "calendar_days": {
      "type": "number",
      "minimum": 0,
      "maximum": 100000
    },
    "cycle_fade_per_full_cycle_percent": {
      "type": "number",
      "minimum": 0,
      "maximum": 10
    },
    "calendar_fade_per_sqrt_year_percent": {
      "type": "number",
      "minimum": 0,
      "maximum": 100
    }
  }
}

Originalschema öffnen

Veröffentlichtes Eingabebeispiel

{
  "initial_capacity_ah": 100,
  "equivalent_full_cycles": 450,
  "average_depth_of_discharge_percent": 70,
  "average_temperature_c": 28,
  "calendar_days": 730,
  "cycle_fade_per_full_cycle_percent": 0.012,
  "calendar_fade_per_sqrt_year_percent": 1.8
}

Ergebnis & Dokumentation

Veröffentlichtes Ergebnisschema anzeigen
{
  "$ref": "https://iot.halowerk.com/v1/battery-degradation/schema#/outputSchema"
}

Veröffentlichtes Ergebnisbeispiel öffnen

Maschinenlesbare Dokumentation dieses Hubs

Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.

Weitere Endpunkte dieses Hubs

Alle Endpunkte dieses Hubs →