Iotwerk
register sentinel value collisions
Return reserved raw codes that collide with the declared valid physical-value interval. Supplied bytes only; no device connection or command.
POST https://iot.halowerk.com/v1/register-sentinel-value-collisionsInputs
| Field | Type | Required | Description |
|---|---|---|---|
| bits | See schema | Yes | |
| signed | boolean | Yes | |
| scale | number | Yes | |
| bias | number | Yes | |
| valid_range | array | Yes | |
| reserved | array | Yes |
Show full input schema
{
"type": "object",
"properties": {
"bits": {
"enum": [
8,
16,
32
]
},
"signed": {
"type": "boolean"
},
"scale": {
"type": "number",
"minimum": 1e-06,
"maximum": 1000000
},
"bias": {
"type": "number",
"minimum": -1000000000,
"maximum": 1000000000
},
"valid_range": {
"type": "array",
"items": {
"type": "number",
"minimum": -1000000000000,
"maximum": 1000000000000
},
"maxItems": 2,
"minItems": 2
},
"reserved": {
"type": "array",
"items": {
"type": "integer",
"minimum": 0,
"maximum": 4294967295
},
"maxItems": 100,
"minItems": 1
}
},
"required": [
"bits",
"signed",
"scale",
"bias",
"valid_range",
"reserved"
],
"additionalProperties": false
}Published input example
{
"bits": 16,
"signed": true,
"scale": 0.1,
"bias": 0,
"valid_range": [
-100,
100
],
"reserved": [
65535,
32767
]
}Result & documentation
Machine-readable documentation of this hub
Source of this page: the published HALOWERK catalog. Updated: 2026-11-18 UTC.
More endpoints in this hub
- Iotwerk0.003 USDC
battery degradation
POSThttps://iot.halowerk.com/v1/battery-degradationApplies a transparent heuristic: cycle fade scales with equivalent full cycles and depth-of-discharge exponent; calendar fade scales with square-root time and a temperature factor. Coefficients are caller supplied or declared defaults. This
- Iotwerk0.002 USDC
device auth
POSThttps://iot.halowerk.com/v1/device-authCanonicalizes device_id, nonce and message, computes an HMAC-SHA256 tag with caller-supplied ephemeral key material, and optionally compares a claimed tag in constant time. It does not provision devices, store keys or replace asymmetric dev
- Iotwerk0.004 USDC
digital twin sync
POSThttps://iot.halowerk.com/v1/digital-twin-syncGroups caller-supplied scalar field changes by field name, selects the highest version, and reports a conflict when equal-version values differ. It does not connect to a twin platform, merge nested documents or resolve semantic conflicts.