R_T = R_si + sum(d/lambda or given R) + R_se, U = 1/R_T (+ caller correction dU). Surface resistances 0.10/0.13/0.17 (upward/horizontal/downward) and 0.04 m2K/W as reproduced from DIN EN ISO 6946 in Wikipedia (CC BY-SA 4.0), overridable. Inhomogeneous layers (e.g. studs and insulation) use global sections with area fractions: upper limit R′_T = 1/sum(f_m/R_T,m), lower limit R″_T with area-weighted conductivity, R_T = (R′_T + R″_T)/2 and the maximum relative error (R′_T - R″_T)/(2 R_T). For a.
POST https://rechen.halowerk.com/v1/u-valueInputs
| Field | Type | Required | Description |
|---|---|---|---|
| layers | array | Yes | Layers from inside to outside. |
| sections | array | No | Area fractions of the sections for inhomogeneous layers (sum 1). |
| heat_flow | string | No | Direction of heat flow (walls: horizontal; roofs/ceilings to cold above: upward; floors over cold: downward). |
| rsi | number | No | Override internal surface resistance (m2K/W). |
| rse | number | No | Override external surface resistance (m2K/W). |
| ventilated_outer_layer | boolean | No | A well-ventilated air layer follows the last listed layer: R_se = R_si. |
| delta_u | number | No | Correction for air gaps, fasteners or inverted roofs (W/(m2K)), determined by the caller. |
| component | string | No | Component type for the GModG Anlage 7 comparison (residential, >= 19 °C). |
Show full input schema
{
"type": "object",
"additionalProperties": false,
"required": [
"layers"
],
"properties": {
"layers": {
"type": "array",
"minItems": 1,
"maxItems": 30,
"description": "Layers from inside to outside.",
"items": {
"type": "object",
"additionalProperties": false,
"required": [
"name"
],
"properties": {
"name": {
"type": "string",
"minLength": 1,
"maxLength": 80
},
"thickness_m": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 5,
"description": "Layer thickness (m)."
},
"lambda": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 500,
"description": "Design thermal conductivity (W/(m K)) of a homogeneous layer."
},
"lambda_by_section": {
"type": "array",
"minItems": 2,
"maxItems": 10,
"items": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 500
},
"description": "Conductivities per section (same order as sections) for an inhomogeneous layer."
},
"r_value": {
"type": "number",
"minimum": 0,
"maximum": 50,
"description": "Thermal resistance (m2K/W) instead of thickness and conductivity, e.g. an unventilated air layer."
}
}
}
},
"sections": {
"type": "array",
"minItems": 2,
"maxItems": 10,
"description": "Area fractions of the sections for inhomogeneous layers (sum 1).",
"items": {
"type": "object",
"additionalProperties": false,
"required": [
"fraction"
],
"properties": {
"name": {
"type": "string",
"maxLength": 60
},
"fraction": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 1
}
}
}
},
"heat_flow": {
"type": "string",
"enum": [
"horizontal",
"upward",
"downward"
],
"default": "horizontal",
"description": "Direction of heat flow (walls: horizontal; roofs/ceilings to cold above: upward; floors over cold: downward)."
},
"rsi": {
"type": "number",
"minimum": 0,
"maximum": 1,
"description": "Override internal surface resistance (m2K/W)."
},
"rse": {
"type": "number",
"minimum": 0,
"maximum": 1,
"description": "Override external surface resistance (m2K/W)."
},
"ventilated_outer_layer": {
"type": "boolean",
"default": false,
"description": "A well-ventilated air layer follows the last listed layer: R_se = R_si."
},
"delta_u": {
"type": "number",
"minimum": 0,
"maximum": 1,
"default": 0,
"description": "Correction for air gaps, fasteners or inverted roofs (W/(m2K)), determined by the caller."
},
"component": {
"type": "string",
"enum": [
"external_wall",
"roof_or_top_floor_ceiling",
"flat_roof_with_sealing",
"wall_or_floor_to_ground_or_unheated",
"floor_build_up_heated_side",
"floor_to_outside_air"
],
"description": "Component type for the GModG Anlage 7 comparison (residential, >= 19 °C)."
}
}
}Published input example
{
"layers": [
{
"name": "gypsum plaster",
"thickness_m": 0.015,
"lambda": 0.7
},
{
"name": "brick",
"thickness_m": 0.24,
"lambda": 0.45
},
{
"name": "EPS",
"thickness_m": 0.14,
"lambda": 0.035
},
{
"name": "render",
"thickness_m": 0.01,
"lambda": 0.87
}
],
"component": "external_wall"
}Result & documentation
Machine-readable documentation of this hub
Source of this page: the published HALOWERK catalog. Updated: 2026-11-17 UTC.
More endpoints in this hub
- Rechenwerk0.003 USDC
ai act risk class
POSThttps://rechen.halowerk.com/v1/ai-act-risk-classEvaluates the caller’s description against Regulation (EU) 2024/1689 as amended by Regulation (EU) 2026/1744: prohibited practices of Art. 5(1)(a)-(h) and the new points (ba) and (bb) (from 2 December 2026); high-risk under Art. 6(1) (safet
- Rechenwerk0.002 USDC
annuity schedule
POSThttps://rechen.halowerk.com/v1/annuity-scheduleMonthly annuity in arrears as used by German banks: rate = loan × (nominal rate + initial repayment rate) / 12, or from a term via A = L·q^n·(q−1)/(q^n−1) with q = 1 + i/12; interest each month = balance × i/12 (30/360), rounded to cents, t
- Rechenwerk0.002 USDC
appeal deadlines
POSThttps://rechen.halowerk.com/v1/appeal-deadlinesCovers only clearly codified periods: Berufung one month and grounds two months (§§ 517, 520(2) ZPO), Revision one and two months (§§ 548, 551(2) ZPO), labour court appeal (§ 66(1) ArbGG), all starting with service of the complete judgment