plug in solar rules

Applies EEG 2023 as amended by Solarpaket I (in force 2024-05-16): devices behind a consumer’s meter with in total up to 2 kW installed (module) capacity and 800 VA inverter output (§ 8(5a)) may be connected without notice to the grid operator; only the Marktstammdatenregister registration within one month of commissioning remains (§ 5(5) MaStRV); they are exempt from technical control duties (§ 9(1) sentence 3, (2) sentence 3), not aggregated with other PV systems (§ 9(3), § 24(1)),.

POST https://rechen.halowerk.com/v1/plug-in-solar-rules

Inputs

Fields of the published input schema
FieldTypeRequiredDescription
module_power_wnumberYesTotal module (peak) power of all plug-in devices at the connection (W).
inverter_power_vanumberYesTotal inverter output of all plug-in devices (VA).
commissioning_datestringNoCommissioning date (default 2026-11-01).
occupancystringNoOwner of a house, tenant or flat owner in a condominium.
meterstringNoExisting meter type.
wants_feed_in_paymentbooleanNoOperator wants a feed-in tariff instead of unpaid acceptance.
Show full input schema
{
  "type": "object",
  "additionalProperties": false,
  "required": [
    "module_power_w",
    "inverter_power_va"
  ],
  "properties": {
    "module_power_w": {
      "type": "number",
      "exclusiveMinimum": 0,
      "maximum": 100000,
      "description": "Total module (peak) power of all plug-in devices at the connection (W)."
    },
    "inverter_power_va": {
      "type": "number",
      "exclusiveMinimum": 0,
      "maximum": 100000,
      "description": "Total inverter output of all plug-in devices (VA)."
    },
    "commissioning_date": {
      "type": "string",
      "format": "date",
      "description": "Commissioning date (default 2026-11-01)."
    },
    "occupancy": {
      "type": "string",
      "enum": [
        "owner_house",
        "tenant",
        "condominium_owner"
      ],
      "default": "owner_house",
      "description": "Owner of a house, tenant or flat owner in a condominium."
    },
    "meter": {
      "type": "string",
      "enum": [
        "ferraris",
        "modern_bidirectional",
        "smart_meter",
        "unknown"
      ],
      "default": "unknown",
      "description": "Existing meter type."
    },
    "wants_feed_in_payment": {
      "type": "boolean",
      "default": false,
      "description": "Operator wants a feed-in tariff instead of unpaid acceptance."
    }
  }
}

Open original schema

Published input example

{
  "module_power_w": 1800,
  "inverter_power_va": 800,
  "commissioning_date": "2026-11-01",
  "occupancy": "tenant"
}

Result & documentation

Machine-readable documentation of this hub

Source of this page: the published HALOWERK catalog. Updated: 2026-11-17 UTC.

More endpoints in this hub