Propwerk
materials lca
Multiplies installed quantities by supplied waste-adjusted production factors and adds tonne-kilometre transport factors. It reports a transparent partial embodied-carbon inventory only; it does not supply verified EPD data, include use/end-of-life stages unless represented by inputs, compare functional equivalence or constitute a certified life-cycle assessment.
POST https://prop.halowerk.com/v1/materials-lcaEingaben
| Feld | Typ | Pflicht | Beschreibung |
|---|---|---|---|
| materials | array | Ja |
Vollständiges Eingabeschema anzeigen
{
"type": "object",
"required": [
"materials"
],
"additionalProperties": false,
"properties": {
"materials": {
"type": "array",
"minItems": 1,
"maxItems": 10000,
"items": {
"type": "object",
"required": [
"material_id",
"installed_mass_kg",
"waste_fraction",
"production_factor_kgco2e_per_kg",
"transport_distance_km",
"transport_factor_kgco2e_per_tonne_km"
],
"additionalProperties": false,
"properties": {
"material_id": {
"type": "string",
"minLength": 1,
"maxLength": 128
},
"installed_mass_kg": {
"type": "number",
"minimum": 0,
"maximum": 1000000000000000
},
"waste_fraction": {
"type": "number",
"minimum": 0,
"maximum": 0.99
},
"production_factor_kgco2e_per_kg": {
"type": "number",
"minimum": -1000000,
"maximum": 1000000
},
"transport_distance_km": {
"type": "number",
"minimum": 0,
"maximum": 10000000
},
"transport_factor_kgco2e_per_tonne_km": {
"type": "number",
"minimum": 0,
"maximum": 1000000
}
}
}
}
}
}Veröffentlichtes Eingabebeispiel
{
"materials": [
{
"material_id": "concrete-c30",
"installed_mass_kg": 480000,
"waste_fraction": 0.04,
"production_factor_kgco2e_per_kg": 0.12,
"transport_distance_km": 45,
"transport_factor_kgco2e_per_tonne_km": 0.09
},
{
"material_id": "rebar",
"installed_mass_kg": 28000,
"waste_fraction": 0.03,
"production_factor_kgco2e_per_kg": 0.78,
"transport_distance_km": 220,
"transport_factor_kgco2e_per_tonne_km": 0.08
}
]
}Ergebnis & Dokumentation
Veröffentlichtes Ergebnisschema anzeigen
{
"$ref": "https://prop.halowerk.com/v1/materials-lca/schema#/outputSchema"
}Veröffentlichtes Ergebnisbeispiel öffnen
Maschinenlesbare Dokumentation dieses Hubs
Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.
Weitere Endpunkte dieses Hubs
- Propwerk0,002 USDC
energy certificate
POSThttps://prop.halowerk.com/v1/energy-certificateSubtracts exported energy from supplied site energy, divides by conditioned floor area and selects the first caller-supplied ascending maximum-intensity band. It does not normalize climate or occupancy, convert primary energy, audit meters
- Propwerk0,004 USDC
flood risk asset
POSThttps://prop.halowerk.com/v1/flood-risk-assetMultiplies each mutually exclusive supplied scenario probability by its supplied damage fraction and asset replacement value, then sums expected loss. It does not obtain hazard maps, model hydrology, validate damage curves, price insurance
- Propwerk0,003 USDC
foot traffic retail
POSThttps://prop.halowerk.com/v1/foot-traffic-retailCompares supplied visits, mean dwell time and conversions with explicit baselines and combines the three ratios using caller-supplied weights. It does not collect location data, count people, infer demographics or forecast demand. Inputs sh