Rechenwerk
heat pump sizing
Required heating output = (design heat load + mean hot-water load) x 24 / (24 - blocking hours). Hot water energy per day = volume x density (Kell 1975) x 4.18 kJ/(kg K) x temperature rise. The heating load line runs linearly from the design load at the design outdoor temperature to zero at the heating limit temperature; with manufacturer capacity points the bivalence point is the intersection of both curves (linear interpolation, no extrapolation). Optional checks: § 43(5) GModG hybrid.
POST https://rechen.halowerk.com/v1/heat-pump-sizingInputs
| Field | Type | Required | Description |
|---|---|---|---|
| design_heat_load_kw | number | Yes | Building heat load at the design outdoor temperature (kW), e.g. from DIN EN 12831-1. |
| design_outdoor_temp_c | number | Yes | Design outdoor temperature of the site (°C). |
| heating_limit_temp_c | number | No | Outdoor temperature above which no space heating is needed (°C). |
| hot_water | object | No | |
| blocking_hours_per_day | number | No | Hours per day the utility may switch the heat pump off (tariff contract). |
| capacity_curve | array | No | Heat pump heating capacity at outdoor temperatures for the planned flow temperature (data sheet). |
| hybrid | object | No | |
| annual_heat_demand_kwh | number | No | Annual heat demand incl. hot water (kWh). |
| seasonal_performance_factor | number | No | Expected seasonal performance factor (JAZ, e.g. per VDI 4650). |
| refrigerant_natural | boolean | No | Uses a natural refrigerant (R290, R600a, R1270, R717, R718, R744). |
| heat_source | string | No | Heat source for the BEG ETAs check (water-based heating). |
| etas_35_percent | number | No | Seasonal space heating energy efficiency ETAs at 35 °C, average climate (ecodesign label data, %). |
| etas_55_percent | number | No | ETAs at 55 °C (%); not required for low-temperature heat pumps. |
| low_temperature_heat_pump | boolean | No | Low-temperature heat pump under the ecodesign rules (only the 35 °C value is checked). |
| installation_year | integer | No | Year of installation (for the BEG refrigerant rule from 2028). |
Show full input schema
{
"type": "object",
"additionalProperties": false,
"required": [
"design_heat_load_kw",
"design_outdoor_temp_c"
],
"properties": {
"design_heat_load_kw": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 10000,
"description": "Building heat load at the design outdoor temperature (kW), e.g. from DIN EN 12831-1."
},
"design_outdoor_temp_c": {
"type": "number",
"minimum": -30,
"maximum": 5,
"description": "Design outdoor temperature of the site (°C)."
},
"heating_limit_temp_c": {
"type": "number",
"minimum": 8,
"maximum": 20,
"default": 15,
"description": "Outdoor temperature above which no space heating is needed (°C)."
},
"hot_water": {
"type": "object",
"additionalProperties": false,
"required": [
"litres_per_day"
],
"properties": {
"litres_per_day": {
"type": "number",
"minimum": 0,
"maximum": 100000,
"description": "Hot water consumption per day (l)."
},
"hot_c": {
"type": "number",
"minimum": 30,
"maximum": 80,
"default": 50
},
"cold_c": {
"type": "number",
"minimum": 0,
"maximum": 25,
"default": 10
},
"loss_factor": {
"type": "number",
"minimum": 1,
"maximum": 3,
"default": 1,
"description": "Factor for storage and circulation losses (1 = none)."
}
}
},
"blocking_hours_per_day": {
"type": "number",
"minimum": 0,
"maximum": 12,
"default": 0,
"description": "Hours per day the utility may switch the heat pump off (tariff contract)."
},
"capacity_curve": {
"type": "array",
"minItems": 2,
"maxItems": 20,
"description": "Heat pump heating capacity at outdoor temperatures for the planned flow temperature (data sheet).",
"items": {
"type": "object",
"additionalProperties": false,
"required": [
"outdoor_c",
"capacity_kw"
],
"properties": {
"outdoor_c": {
"type": "number",
"minimum": -30,
"maximum": 30
},
"capacity_kw": {
"type": "number",
"minimum": 0,
"maximum": 10000
}
}
}
},
"hybrid": {
"type": "object",
"additionalProperties": false,
"required": [
"capacity_point_a_kw",
"peak_generator_kw",
"operation"
],
"properties": {
"capacity_point_a_kw": {
"type": "number",
"minimum": 0,
"maximum": 10000,
"description": "Heat pump output at part load point A under DIN EN 14825 (data sheet)."
},
"peak_generator_kw": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 10000
},
"operation": {
"type": "string",
"enum": [
"parallel",
"partly_parallel",
"alternative"
]
}
}
},
"annual_heat_demand_kwh": {
"type": "number",
"minimum": 0,
"maximum": 100000000,
"description": "Annual heat demand incl. hot water (kWh)."
},
"seasonal_performance_factor": {
"type": "number",
"minimum": 1,
"maximum": 10,
"description": "Expected seasonal performance factor (JAZ, e.g. per VDI 4650)."
},
"refrigerant_natural": {
"type": "boolean",
"description": "Uses a natural refrigerant (R290, R600a, R1270, R717, R718, R744)."
},
"heat_source": {
"type": "string",
"enum": [
"air",
"ground",
"water",
"other"
],
"description": "Heat source for the BEG ETAs check (water-based heating)."
},
"etas_35_percent": {
"type": "number",
"minimum": 50,
"maximum": 400,
"description": "Seasonal space heating energy efficiency ETAs at 35 °C, average climate (ecodesign label data, %)."
},
"etas_55_percent": {
"type": "number",
"minimum": 50,
"maximum": 400,
"description": "ETAs at 55 °C (%); not required for low-temperature heat pumps."
},
"low_temperature_heat_pump": {
"type": "boolean",
"default": false,
"description": "Low-temperature heat pump under the ecodesign rules (only the 35 °C value is checked)."
},
"installation_year": {
"type": "integer",
"minimum": 2024,
"maximum": 2035,
"description": "Year of installation (for the BEG refrigerant rule from 2028)."
}
}
}Published input example
{
"design_heat_load_kw": 8,
"design_outdoor_temp_c": -12,
"hot_water": {
"litres_per_day": 200
},
"blocking_hours_per_day": 2,
"capacity_curve": [
{
"outdoor_c": -15,
"capacity_kw": 5
},
{
"outdoor_c": -7,
"capacity_kw": 6
},
{
"outdoor_c": 2,
"capacity_kw": 7.5
},
{
"outdoor_c": 7,
"capacity_kw": 8.5
}
]
}Result & documentation
Machine-readable documentation of this hub
Source of this page: the published HALOWERK catalog. Updated: 2026-11-17 UTC.
More endpoints in this hub
- Rechenwerk0.003 USDC
ai act risk class
POSThttps://rechen.halowerk.com/v1/ai-act-risk-classEvaluates the caller’s description against Regulation (EU) 2024/1689 as amended by Regulation (EU) 2026/1744: prohibited practices of Art. 5(1)(a)-(h) and the new points (ba) and (bb) (from 2 December 2026); high-risk under Art. 6(1) (safet
- Rechenwerk0.002 USDC
annuity schedule
POSThttps://rechen.halowerk.com/v1/annuity-scheduleMonthly annuity in arrears as used by German banks: rate = loan × (nominal rate + initial repayment rate) / 12, or from a term via A = L·q^n·(q−1)/(q^n−1) with q = 1 + i/12; interest each month = balance × i/12 (30/360), rounded to cents, t
- Rechenwerk0.002 USDC
appeal deadlines
POSThttps://rechen.halowerk.com/v1/appeal-deadlinesCovers only clearly codified periods: Berufung one month and grounds two months (§§ 517, 520(2) ZPO), Revision one and two months (§§ 548, 551(2) ZPO), labour court appeal (§ 66(1) ArbGG), all starting with service of the complete judgment