Skip to content
HALOWERK

Climate and Emissions

heat periodic wall penetration

Return attenuation, phase lag and temperature response at supplied depths in a semi-infinite periodically heated wall.

POST https://klima.halowerk.com/v1/heat-periodic-wall-penetration

Inputs

Fields of the published input schema
FieldTypeRequiredDescription
alphanumberYes
periodnumberYes
depthsarrayYes
meannumberYes
amplitudenumberYes
timesarrayYes
Show full input schema
{
  "type": "object",
  "properties": {
    "alpha": {
      "type": "number",
      "minimum": 1e-06,
      "maximum": 1000000000
    },
    "period": {
      "type": "number",
      "minimum": 1e-06,
      "maximum": 1000000000
    },
    "depths": {
      "type": "array",
      "items": {
        "type": "number",
        "minimum": 0,
        "maximum": 1000000
      },
      "maxItems": 100,
      "minItems": 1
    },
    "mean": {
      "type": "number",
      "minimum": -1e+30,
      "maximum": 1e+30
    },
    "amplitude": {
      "type": "number",
      "minimum": 0,
      "maximum": 1000000
    },
    "times": {
      "type": "array",
      "items": {
        "type": "number",
        "minimum": 0,
        "maximum": 1000000000
      },
      "maxItems": 100,
      "minItems": 1
    }
  },
  "required": [
    "alpha",
    "period",
    "depths",
    "mean",
    "amplitude",
    "times"
  ],
  "additionalProperties": false
}

Open original schema

Published input example

{
  "alpha": 1,
  "period": 6.283185307179586,
  "depths": [
    0,
    1
  ],
  "mean": 0,
  "amplitude": 1,
  "times": [
    0
  ]
}

Result & documentation

Machine-readable documentation of this hub

Source of this page: the published HALOWERK catalog. Updated: 2026-11-19 UTC.

More endpoints in this hub