Skip to content
HALOWERK

Rechenwerk

geg heating rules

Applies §§ 42-46 GModG (Act of 23.07.2026, BGBl. 2026 I Nr. 226): gas, oil or LPG heating installed after 2026-07-29 must use at least 10 % (2029), 15 % (2030), 30 % (2035) and 60 % (2040) biomethane, bio-oil, biogenic LPG or green/blue/orange/turquoise hydrogen; solar thermal (0.04/0.03 m2 aperture per m2 floor area) or ventilation heat recovery (>= 73 %, COP >= 10) fulfil it 2029-2034; heat-pump hybrids fulfil it with >= 30 % (parallel) or >= 40 % (alternative) of the peak generator output.

POST https://rechen.halowerk.com/v1/geg-heating-rules

Inputs

Fields of the published input schema
FieldTypeRequiredDescription
buildingstringYesexisting building or new building (§ 10 GModG).
installation_datestringYesDate the heating system is installed (from 2026-07-29 to 2030-12-31).
heatingstringYesOption under § 42(2) GModG: gas_oil_lpg_boiler, heat_pump, solar_thermal, biomass (solid biomass), hydrogen (heating for green/blue/orange/turquoise hydrogen), heat_pump_hybrid (heat pump + gas/oil/LPG peak boiler), solar_hybrid (solar thermal + gas/oil/LPG), biomass_hybrid (solid biomass + gas/oil/LPG), chp (high-efficiency CHP), direct_electric, heat_network_connection, other_innovative.
chp_fuelstringNoFor chp: fuel of the CHP unit.
dwellingsintegerNoNumber of dwellings or other independent units in the building.
residentialbooleanNoResidential building (Wohngebäude).
owner_occupies_one_of_max_twobooleanNoBuilding with at most two dwellings, one occupied by the owner (exceptions for direct electric heating).
envelope_better_than_required_percentnumberNoFor direct_electric: how much the building falls below the building-envelope requirements of §§ 16 and 19 GModG (percent).
replaces_single_room_direct_electricbooleanNoFor direct_electric in existing buildings: replacement of an existing single-room direct electric heater (§ 46(2)).
hybridobjectNoFor heat_pump_hybrid.
solarobjectNoSolar thermal system used for § 43(3).
ventilationobjectNoVentilation with heat recovery used for § 43(4).
irreparable_failurebooleanNoInstallation because the previous heating failed irreparably (§ 43(7)).
Show full input schema
{
  "type": "object",
  "additionalProperties": false,
  "required": [
    "building",
    "installation_date",
    "heating"
  ],
  "properties": {
    "building": {
      "type": "string",
      "enum": [
        "existing",
        "new"
      ],
      "description": "existing building or new building (§ 10 GModG)."
    },
    "installation_date": {
      "type": "string",
      "format": "date",
      "description": "Date the heating system is installed (from 2026-07-29 to 2030-12-31)."
    },
    "heating": {
      "type": "string",
      "enum": [
        "gas_oil_lpg_boiler",
        "heat_pump",
        "solar_thermal",
        "biomass",
        "hydrogen",
        "heat_pump_hybrid",
        "solar_hybrid",
        "biomass_hybrid",
        "chp",
        "direct_electric",
        "heat_network_connection",
        "other_innovative"
      ],
      "description": "Option under § 42(2) GModG: gas_oil_lpg_boiler, heat_pump, solar_thermal, biomass (solid biomass), hydrogen (heating for green/blue/orange/turquoise hydrogen), heat_pump_hybrid (heat pump + gas/oil/LPG peak boiler), solar_hybrid (solar thermal + gas/oil/LPG), biomass_hybrid (solid biomass + gas/oil/LPG), chp (high-efficiency CHP), direct_electric, heat_network_connection, other_innovative."
    },
    "chp_fuel": {
      "type": "string",
      "enum": [
        "gas_oil_lpg",
        "biomass_or_hydrogen"
      ],
      "description": "For chp: fuel of the CHP unit."
    },
    "dwellings": {
      "type": "integer",
      "minimum": 1,
      "maximum": 10000,
      "default": 1,
      "description": "Number of dwellings or other independent units in the building."
    },
    "residential": {
      "type": "boolean",
      "default": true,
      "description": "Residential building (Wohngebäude)."
    },
    "owner_occupies_one_of_max_two": {
      "type": "boolean",
      "default": false,
      "description": "Building with at most two dwellings, one occupied by the owner (exceptions for direct electric heating)."
    },
    "envelope_better_than_required_percent": {
      "type": "number",
      "minimum": 0,
      "maximum": 100,
      "description": "For direct_electric: how much the building falls below the building-envelope requirements of §§ 16 and 19 GModG (percent)."
    },
    "replaces_single_room_direct_electric": {
      "type": "boolean",
      "default": false,
      "description": "For direct_electric in existing buildings: replacement of an existing single-room direct electric heater (§ 46(2))."
    },
    "hybrid": {
      "type": "object",
      "additionalProperties": false,
      "required": [
        "heat_pump_kw_point_a",
        "peak_generator_kw",
        "operation"
      ],
      "description": "For heat_pump_hybrid.",
      "properties": {
        "heat_pump_kw_point_a": {
          "type": "number",
          "exclusiveMinimum": 0,
          "maximum": 100000,
          "description": "Heat pump output at part load point A under DIN EN 14825 (kW, from the data sheet)."
        },
        "peak_generator_kw": {
          "type": "number",
          "exclusiveMinimum": 0,
          "maximum": 100000,
          "description": "Output of the peak load generator (kW)."
        },
        "operation": {
          "type": "string",
          "enum": [
            "parallel",
            "partly_parallel",
            "alternative"
          ],
          "description": "Bivalent operating mode."
        }
      }
    },
    "solar": {
      "type": "object",
      "additionalProperties": false,
      "required": [
        "aperture_m2",
        "useful_floor_area_m2"
      ],
      "description": "Solar thermal system used for § 43(3).",
      "properties": {
        "aperture_m2": {
          "type": "number",
          "minimum": 0,
          "maximum": 100000
        },
        "useful_floor_area_m2": {
          "type": "number",
          "exclusiveMinimum": 0,
          "maximum": 10000000
        }
      }
    },
    "ventilation": {
      "type": "object",
      "additionalProperties": false,
      "required": [
        "heat_recovery_percent",
        "coefficient_of_performance",
        "whole_building"
      ],
      "description": "Ventilation with heat recovery used for § 43(4).",
      "properties": {
        "heat_recovery_percent": {
          "type": "number",
          "minimum": 0,
          "maximum": 100
        },
        "coefficient_of_performance": {
          "type": "number",
          "minimum": 0,
          "maximum": 100
        },
        "whole_building": {
          "type": "boolean"
        }
      }
    },
    "irreparable_failure": {
      "type": "boolean",
      "default": false,
      "description": "Installation because the previous heating failed irreparably (§ 43(7))."
    }
  }
}

Open original schema

Published input example

{
  "building": "existing",
  "installation_date": "2026-11-15",
  "heating": "gas_oil_lpg_boiler",
  "dwellings": 1
}

Result & documentation

Machine-readable documentation of this hub

Source of this page: the published HALOWERK catalog. Updated: 2026-11-17 UTC.

More endpoints in this hub

All endpoints in this hub →