Technische Prüfungen & Formate
F TD2000 ENGINEERING B002 / sensible two stream effectiveness ntu outlet equilibrium
Published sensible constant-capacity epsilon NTU relationships for counterflow, parallel and crossflow both unmixed in one capability; explicit zero UA and equal counterflow capacity limits. Return heat rate, outlet temperatures, capacity ratio. No condensation or changing properties.
POST https://detect.halowerk.com/v1/F-TD2000-ENGINEERING-B002/sensible-two-stream-effectiveness-ntu-outlet-equilibriumEingaben
| Feld | Typ | Pflicht | Beschreibung |
|---|---|---|---|
| artifact | object | Ja | UTF8 JSON artifact at most16000 bytes, computed result20000 bytes; unknown for derived out-of-domain, singular or ill-conditioned systems. Numeric result rounded six decimals. Published sensible constant-capacity epsilon NTU relationships for counterflow, parallel and crossflow both unmixed in one capability; explicit zero UA and equal counterflow capacity limits. Return heat rate, outlet temperatures, capacity ratio. No condensation or changing properties. |
Vollständiges Eingabeschema anzeigen
{
"type": "object",
"additionalProperties": false,
"required": [
"artifact"
],
"properties": {
"artifact": {
"type": "object",
"additionalProperties": false,
"required": [
"heatExchanger"
],
"properties": {
"heatExchanger": {
"type": "object",
"additionalProperties": false,
"required": [
"data",
"claim"
],
"properties": {
"data": {
"type": "object",
"additionalProperties": false,
"required": [
"configuration",
"UA",
"hot_capacity",
"cold_capacity",
"hot_inlet",
"cold_inlet"
],
"properties": {
"configuration": {
"enum": [
"counter",
"parallel",
"cross_both_unmixed"
]
},
"UA": {
"type": "number",
"minimum": 0,
"maximum": 10000000
},
"hot_capacity": {
"type": "number",
"minimum": 0.001,
"maximum": 10000000
},
"cold_capacity": {
"type": "number",
"minimum": 0.001,
"maximum": 10000000
},
"hot_inlet": {
"type": "number",
"minimum": 150,
"maximum": 2000
},
"cold_inlet": {
"type": "number",
"minimum": 150,
"maximum": 2000
}
}
},
"claim": {}
}
}
},
"description": "UTF8 JSON artifact at most16000 bytes, computed result20000 bytes; unknown for derived out-of-domain, singular or ill-conditioned systems. Numeric result rounded six decimals. Published sensible constant-capacity epsilon NTU relationships for counterflow, parallel and crossflow both unmixed in one capability; explicit zero UA and equal counterflow capacity limits. Return heat rate, outlet temperatures, capacity ratio. No condensation or changing properties."
}
}
}Ergebnis & Dokumentation
Maschinenlesbare Dokumentation dieses Hubs
Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.
Weitere Endpunkte dieses Hubs
- Technische Prüfungen & Formate0,003 USDC
aria concrete role property support closure
POSThttps://detect.halowerk.com/u/aria-concrete-role-property-support-closureA component API exporter needs properties that are unsupported or prohibited for its selected explicit ARIA role rather than losing them silently during conversion.
- Technische Prüfungen & Formate0,003 USDC
aria description author source precedence
POSThttps://detect.halowerk.com/u/aria-description-author-source-precedenceA description-metadata exporter needs which author ARIA source survives precedence and which competing source is overridden before transferring help text.
- Technische Prüfungen & Formate0,003 USDC
aria explicit concrete role token fallback
POSThttps://detect.halowerk.com/u/aria-explicit-concrete-role-token-fallbackBefore removing compatibility role tokens, a website migration agent needs which concrete source role survives the normative fallback order.