Medwerk
drug recall
Searches the FDA enforcement database for drug recalls matching a product name, company or date range and returns each with the classification leading: class one means use can cause serious harm or death, class three means it will not, and a recall for a wrong label colour and one for contamination share only the word. The class is therefore returned with its meaning spelled out rather than as a bare code. Each record carries the reason for the recall as reported, the recalling firm, the.
POST https://med.halowerk.com/v1/drug-recallEingaben
| Feld | Typ | Pflicht | Beschreibung |
|---|---|---|---|
| product | string | Nein | Product or drug name. |
| company | string | Nein | Recalling firm. |
| classification | string | Nein | Restrict to one class. |
| since | string | Nein | ISO date; defaults to two years back. |
| status | string | Nein | |
| limit | integer | Nein |
Vollständiges Eingabeschema anzeigen
{
"type": "object",
"additionalProperties": false,
"properties": {
"product": {
"type": "string",
"maxLength": 200,
"description": "Product or drug name."
},
"company": {
"type": "string",
"maxLength": 200,
"description": "Recalling firm."
},
"classification": {
"type": "string",
"enum": [
"Class I",
"Class II",
"Class III"
],
"description": "Restrict to one class."
},
"since": {
"type": "string",
"maxLength": 10,
"description": "ISO date; defaults to two years back."
},
"status": {
"type": "string",
"enum": [
"Ongoing",
"Completed",
"Terminated"
]
},
"limit": {
"type": "integer",
"minimum": 1,
"maximum": 100,
"default": 30
}
}
}Veröffentlichtes Eingabebeispiel
{
"product": "metformin",
"limit": 30
}Ergebnis & Dokumentation
Maschinenlesbare Dokumentation dieses Hubs
Quelle dieser Seite: der veröffentlichte HALOWERK-Katalog. Stand: 2026-11-01, 15:19 UTC.
Weitere Endpunkte dieses Hubs
- Medwerk0,006 USDC
adverse events
POSThttps://med.halowerk.com/v1/adverse-eventsSummarises adverse event reports for a drug: the most frequently reported reactions, the distribution of serious outcomes, the split between reports from health professionals and consumers, and the trend over time. Three limitations are ret
- Medwerk0,005 USDC
boxed warning
POSThttps://med.halowerk.com/v1/boxed-warningAnswers whether a drug carries a boxed warning, the strongest warning class the FDA applies, and returns the warning text with the label version it came from. The check runs across multiple labels for the same substance rather than the firs
- Medwerk0,006 USDC
chemical hazard
POSThttps://med.halowerk.com/v1/chemical-hazardReturns the hazard profile of a chemical: GHS pictograms, signal word, hazard statements and precautionary statements where they are recorded, together with the physical properties that govern handling — melting and boiling point, flash poi