Rechenwerk
condensation risk
Temperature profile from the thermal resistances (R_si, d/lambda, R_se); saturation vapour pressure per interface by the Magnus formula (WMO-No. 8, Annex 4.B; over ice below 0 °C); vapour diffusion equivalent air layer thickness s_d = mu x d per layer. The vapour pressure curve is the lower convex hull of the interior and exterior partial pressures and the saturation points (Glaser tangent construction); interfaces where it touches saturation are condensation planes. Condensation rate per.
POST https://rechen.halowerk.com/v1/condensation-riskInputs
| Field | Type | Required | Description |
|---|---|---|---|
| layers | array | Yes | Layers from inside to outside. |
| inside | object | Yes | |
| outside | object | Yes | |
| rsi | number | No | Internal surface resistance (m2K/W). |
| rse | number | No | External surface resistance (m2K/W). |
| air_vapour_permeability | number | No | Water vapour permeability of still air delta_a (kg/(m s Pa)); default from Schirmer at the mean temperature. |
| period_hours | number | No | Duration of the climate case (h) for the condensate mass. |
Show full input schema
{
"type": "object",
"additionalProperties": false,
"required": [
"layers",
"inside",
"outside"
],
"properties": {
"layers": {
"type": "array",
"minItems": 1,
"maxItems": 30,
"description": "Layers from inside to outside.",
"items": {
"type": "object",
"additionalProperties": false,
"required": [
"name"
],
"properties": {
"name": {
"type": "string",
"minLength": 1,
"maxLength": 80
},
"thickness_m": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 5
},
"lambda": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 500,
"description": "Thermal conductivity (W/(m K))."
},
"mu": {
"type": "number",
"minimum": 0,
"maximum": 10000000,
"description": "Water vapour diffusion resistance factor."
},
"r_value": {
"type": "number",
"minimum": 0,
"maximum": 50,
"description": "Thermal resistance instead of thickness/lambda (m2K/W)."
},
"sd_m": {
"type": "number",
"minimum": 0,
"maximum": 100000,
"description": "Vapour diffusion equivalent air layer thickness instead of mu (m), e.g. membranes."
}
}
}
},
"inside": {
"type": "object",
"additionalProperties": false,
"required": [
"temperature_c",
"relative_humidity_percent"
],
"properties": {
"temperature_c": {
"type": "number",
"minimum": -40,
"maximum": 60
},
"relative_humidity_percent": {
"type": "number",
"minimum": 0,
"maximum": 100
}
}
},
"outside": {
"type": "object",
"additionalProperties": false,
"required": [
"temperature_c",
"relative_humidity_percent"
],
"properties": {
"temperature_c": {
"type": "number",
"minimum": -40,
"maximum": 60
},
"relative_humidity_percent": {
"type": "number",
"minimum": 0,
"maximum": 100
}
}
},
"rsi": {
"type": "number",
"minimum": 0,
"maximum": 1,
"default": 0.13,
"description": "Internal surface resistance (m2K/W)."
},
"rse": {
"type": "number",
"minimum": 0,
"maximum": 1,
"default": 0.04,
"description": "External surface resistance (m2K/W)."
},
"air_vapour_permeability": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 1e-08,
"description": "Water vapour permeability of still air delta_a (kg/(m s Pa)); default from Schirmer at the mean temperature."
},
"period_hours": {
"type": "number",
"minimum": 0,
"maximum": 8784,
"description": "Duration of the climate case (h) for the condensate mass."
}
}
}Published input example
{
"layers": [
{
"name": "concrete",
"thickness_m": 0.2,
"lambda": 2,
"mu": 80
},
{
"name": "mineral wool",
"thickness_m": 0.1,
"lambda": 0.04,
"mu": 1
},
{
"name": "vapour-tight cladding",
"thickness_m": 0.01,
"lambda": 1,
"mu": 1000
}
],
"inside": {
"temperature_c": 20,
"relative_humidity_percent": 50
},
"outside": {
"temperature_c": -5,
"relative_humidity_percent": 80
},
"period_hours": 2160
}Result & documentation
Machine-readable documentation of this hub
Source of this page: the published HALOWERK catalog. Updated: 2026-11-17 UTC.
More endpoints in this hub
- Rechenwerk0.003 USDC
ai act risk class
POSThttps://rechen.halowerk.com/v1/ai-act-risk-classEvaluates the caller’s description against Regulation (EU) 2024/1689 as amended by Regulation (EU) 2026/1744: prohibited practices of Art. 5(1)(a)-(h) and the new points (ba) and (bb) (from 2 December 2026); high-risk under Art. 6(1) (safet
- Rechenwerk0.002 USDC
annuity schedule
POSThttps://rechen.halowerk.com/v1/annuity-scheduleMonthly annuity in arrears as used by German banks: rate = loan × (nominal rate + initial repayment rate) / 12, or from a term via A = L·q^n·(q−1)/(q^n−1) with q = 1 + i/12; interest each month = balance × i/12 (30/360), rounded to cents, t
- Rechenwerk0.002 USDC
appeal deadlines
POSThttps://rechen.halowerk.com/v1/appeal-deadlinesCovers only clearly codified periods: Berufung one month and grounds two months (§§ 517, 520(2) ZPO), Revision one and two months (§§ 548, 551(2) ZPO), labour court appeal (§ 66(1) ArbGG), all starting with service of the complete judgment