Rechenwerk
co2 cost split
Residential buildings: specific emissions = kg CO2 of the billing period / living area, rounded to one decimal (§ 5(1) CO2KostAufG), classified in the table of the Anlage (BGBl. I 2022, 2159; unchanged by the amendment of 23 Jul 2026): below 12 kg the tenant bears 100 %, then landlord 10, 20, 30, 40, 50, 60, 70, 80 % per 5 kg step and 95 % from 52 kg; thresholds scaled for billing periods shorter than a year (§ 5(1) sentence 4). Non-residential buildings: landlord 50 % (§ 8). Public-law.
POST https://rechen.halowerk.com/v1/co2-cost-splitInputs
| Field | Type | Required | Description |
|---|---|---|---|
| building_type | string | Yes | residential = mainly residential building (§ 5); non_residential = § 8. |
| co2_emissions_kg | number | Yes | CO2 emissions of the heating fuel or heat supply for the billing period in kg (from the supplier invoices, § 3(1) no. 1). |
| area_m2 | number | Yes | Living area of the building (or of the separately supplied flat) in m². |
| co2_cost_eur | number | No | CO2 cost component of the invoices in EUR incl. VAT; if omitted it is computed from the certificate price. |
| delivery_year | integer | No | Year of the fuel delivery for the certificate price (required if co2_cost_eur is omitted). |
| vat_percent | number | No | VAT rate applied to the computed CO2 cost. |
| billing_period_days | integer | No | Length of the billing period; below one year the step thresholds are reduced proportionally. |
| restrictions | string | No | Public-law restrictions (listed building, mandatory district heating, preservation statute) against a substantial energy improvement of the building or of the heat supply (§ 9). |
| tenant_cost_share_percent | number | No | Share of the building heating costs billed to one tenant, to compute that tenant amount. |
Show full input schema
{
"type": "object",
"additionalProperties": false,
"required": [
"building_type",
"co2_emissions_kg",
"area_m2"
],
"properties": {
"building_type": {
"type": "string",
"enum": [
"residential",
"non_residential"
],
"description": "residential = mainly residential building (§ 5); non_residential = § 8."
},
"co2_emissions_kg": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 1000000000,
"description": "CO2 emissions of the heating fuel or heat supply for the billing period in kg (from the supplier invoices, § 3(1) no. 1)."
},
"area_m2": {
"type": "number",
"exclusiveMinimum": 0,
"maximum": 10000000,
"description": "Living area of the building (or of the separately supplied flat) in m²."
},
"co2_cost_eur": {
"type": "number",
"minimum": 0,
"maximum": 1000000000,
"description": "CO2 cost component of the invoices in EUR incl. VAT; if omitted it is computed from the certificate price."
},
"delivery_year": {
"type": "integer",
"minimum": 2023,
"maximum": 2026,
"description": "Year of the fuel delivery for the certificate price (required if co2_cost_eur is omitted)."
},
"vat_percent": {
"type": "number",
"minimum": 0,
"maximum": 25,
"default": 19,
"description": "VAT rate applied to the computed CO2 cost."
},
"billing_period_days": {
"type": "integer",
"minimum": 1,
"maximum": 366,
"default": 365,
"description": "Length of the billing period; below one year the step thresholds are reduced proportionally."
},
"restrictions": {
"type": "string",
"enum": [
"none",
"building_or_supply",
"both"
],
"default": "none",
"description": "Public-law restrictions (listed building, mandatory district heating, preservation statute) against a substantial energy improvement of the building or of the heat supply (§ 9)."
},
"tenant_cost_share_percent": {
"type": "number",
"minimum": 0,
"maximum": 100,
"description": "Share of the building heating costs billed to one tenant, to compute that tenant amount."
}
}
}Published input example
{
"building_type": "residential",
"co2_emissions_kg": 30000,
"area_m2": 1000,
"co2_cost_eur": 1620
}Result & documentation
Machine-readable documentation of this hub
Source of this page: the published HALOWERK catalog. Updated: 2026-11-17 UTC.
More endpoints in this hub
- Rechenwerk0.003 USDC
ai act risk class
POSThttps://rechen.halowerk.com/v1/ai-act-risk-classEvaluates the caller’s description against Regulation (EU) 2024/1689 as amended by Regulation (EU) 2026/1744: prohibited practices of Art. 5(1)(a)-(h) and the new points (ba) and (bb) (from 2 December 2026); high-risk under Art. 6(1) (safet
- Rechenwerk0.002 USDC
annuity schedule
POSThttps://rechen.halowerk.com/v1/annuity-scheduleMonthly annuity in arrears as used by German banks: rate = loan × (nominal rate + initial repayment rate) / 12, or from a term via A = L·q^n·(q−1)/(q^n−1) with q = 1 + i/12; interest each month = balance × i/12 (30/360), rounded to cents, t
- Rechenwerk0.002 USDC
appeal deadlines
POSThttps://rechen.halowerk.com/v1/appeal-deadlinesCovers only clearly codified periods: Berufung one month and grounds two months (§§ 517, 520(2) ZPO), Revision one and two months (§§ 548, 551(2) ZPO), labour court appeal (§ 66(1) ArbGG), all starting with service of the complete judgment